What Can I Do If My E-Paper Display (EPD) Does Not Update?
There can be several reasons why your E-Paper Display is not updating. Check the following items in order:
1. Is the Battery Charged?
Connect the EPD to USB to charge the battery. Keep it connected to USB during the following tests.
2. Is the EPD Configured?
Follow the instructions for setting up the EPD in a browser to connect it to Wi-Fi and MQTT.
3. Is the EPD Connected to Wi-Fi?
Check your Wi-Fi hardware to see whether the EPD is connected.
If the EPD does not connect to Wi-Fi, check the Wi-Fi settings.
4. Is the EPD Connected to MQTT?
Check the iSign device information or use an external MQTT client, such as MQTT Explorer, to see whether the EPD connects to MQTT.
If the EPD does not connect to MQTT, check the MQTT settings.
5. Is the EPD Set Up in iSign?
Check the iSign server to see whether the EPD has been set up. If it has not, add it and make sure to use the correct topic.
6. Is Content Scheduled for the EPD in iSign?
Schedule content for the EPD in iSign. After the EPD has been charged, it may take up to 2 minutes to respond to a schedule change.