The EPD user interface consists of a button, two LEDs (blue and red), and a USB-C port.

Operating Modes​

The EPD has two operating modes:

Power sourceBehavior
USB-CAlways on. The web interface is available and the MQTT connection remains active.
BatteryActive briefly (2 seconds), then sleeps. There is no MQTT connection or web interface while the device is asleep.

Blue LED​

The blue LED indicates the charging status. Charge the device through the USB-C port.

Blue LEDBattery
OnCharging
OffDischarging

Button and Red LED​

The button provides basic controls. The device responds differently to short and long presses and to button sequences.

The red LED indicates the system status. In battery mode, it also indicates when the EPD wakes briefly.

Button pressFunctionLED
ShortWake, connect, update, then sleepBriefly on
5 secondsReset Wi-Fi2 short flashes
10 secondsRestore factory settings2 short flashes
1 second, then 1 secondRun the factory test

USB-C​

The USB-C port is primarily used for charging. It can also provide continuous power to the device.

You can also use USB-C to program and configure the device and for diagnostics and service. See the EPD FWUpdate Tool.