Configure EPDs with the FWUpdate Tool
This article requires some technical experience.
Note: Starting with FWUpdate Tool version 1.3.0, a password is required to improve access security. Enter the EPD's ID as the password.
Use the FWUpdate configuration module to configure a large number of EPDs quickly and efficiently. Automated settings and batch configuration simplify the process and save time and effort.
Preparation
Content is assigned to EPDs, and each display has a unique ID. We recommend recording the ID together with the location and room name, especially for door signs that are labeled and remain in the same room. After the displays connect to the server, you can enter their location names manually in the list under Administration > EPD.
All files provided here are examples. Adapt them to your own environment.
Download the FWUpdate Tool
Download FWUpdate and extract the archive to a folder of your choice. For more information, see EPD FWUpdate Tool.
JSON Configuration File
Store the configuration data for your EPDs in a JSON file. Create a text file named epd.json and add the following content:
{
"wifi": {
"ssid": "MY_WIFI_SSID",
"password": "MY_WIFI_PASSWORD",
"roaming": true
},
"mqtt": {
"url": "MY_MQTT_URL",
"username": "MY_MQTT_USER",
"password": "MY_MQTT_PASSWORD"
},
"app": {
"sleep_sec": 3600
}
}
Replace the UPPERCASE terms with the values used in your system.
The MQTT URL usually looks like mqtts://my.domain:8883 or mqtt://my.domain:1883.
We recommend using an editor with syntax highlighting to edit the JSON file, such as Visual Studio Code.
Create the configuration file once, then apply it to all EPDs.
Apply the Configuration
The following examples are for Windows. For instructions on using the tool on Linux, see EPD FWUpdate Tool.
Connect the EPD to your PC using a USB-C cable.
Right-click the FWUpdate folder and select Open in Terminal from the context menu. A terminal window opens.
Run the following command and press <Enter> to confirm:
.\fwupdate program --config epd.json --verify --bulk
The configuration tool configures the EPD and displays a success message when it is done.
You can now disconnect the EPD from USB-C.
Connect the next EPD to the USB port and repeat the process until all EPDs are configured.