Reset a Device to Factory Settings

If you want to reset a device to factory settings before setting it up again, you have several options. The easiest is to use the button. For a reliable reset, users with technical experience can use the FWUpdate Tool.

Reset Using the Button​

There is a button on the back of each EPD. Press and hold it for 10 seconds. The LED flashes twice, and the device is reset to factory settings.

info

Tip: Use a ballpoint pen with the tip retracted to press the button.

Reset Using the FWUpdate Tool​

tip

This section requires some technical experience.

  1. Download and extract the EPD FWUpdate Tool. Version 1.2.7 or later is required.

  2. Connect the EPD to your PC using a USB cable.

  3. Run the following command:

    ./fwupdate program --firmware IE042B/1.2.7 --download --wipe-data

    Replace IE042B with your model, such as IE075B or IE116R.

  4. Answer the questions in the console.

The EPD is now back at factory settings.